    Cyrix-Li-Charge 230A Battery Combiner will disengage immediately whenever its control input becomes free floating, signaling cell over voltage or cell over temperature.

    In general a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay of 3 seconds. After two attempts to reengage with 3 seconds delay, the delay increases to 10 minutes.

    Whenever battery voltage is less than 13,5V (resp. 27V or 54V), the Cyrix will disengage with a delay of 1 hour.Note 1: In case of zero discharge current, or a small discharge current, the Cyrix will not disengage shortly after the charger has been switched off and/or disconnected, because battery voltage will remain higher than 13,5V.Note 2: If, after the Cyrix has disengaged, the output of the battery charger immediately increases to 13,7V or more, the Cyrix will reengage, with 3 seconds delay.

    Part Numbers: 

    • Cyrix-Li-Charge 12/24V: CYR020230450
    • Cyrix-Li-Charge 24/48V: CYR010230430